A+++ 14kw R32 Tap Hot Water Geyser Boiler Room Heating Evi Air to Water Heat Pump All in One Water Heater System
Features of A+++ 14kw R32 Tap Hot Water Geyser Boiler Room Heating Evi Air to Water Heat Pump All in One Water Heater System
1. Enhanced Vapors Injection (EVI) technology: enable heat pump work constantly and steadily at extrem weather condition -35DegC, adopting the most advanced low temperature EVI Copeland compressor and related technology.
2. Green, high efficient and ECO refrigerants, R290/R32/R410A, are compatible.
3. Wide temperature and power supply range of temperature: -30DegC to 43DegC, 220v-240v/50-60hz/1ph, which is widely used in different environment condition and area.
4. Higher heating capacity: plus-size evaporator extracting more heat energy from air increase 20% to perform outstanding COP.
5. WIFI remote control, free of distances.
6. Advanced Operate System, Moto IC, automatic start-up anti-freezing protection when the ambient is below zero DegC, the unit is in standby mode more than 30 minutes, automatic anti-freezing device will be started up so that the unit will be protected in lower ambient temperature.
7. Weekly automatic sterilization function, ensure hot water circulation system green and healthy for daily usage.
8. 60DegC maximum water temperature outlet, available to projects for either house heating in extrem weather condition or 4-season domastic hot water requirement.
9. All in One compact design with water tank built-in saving rooms and installation cost, well protecting on key parts away from frozen crack in all kinds of extrem air conditions.
Specification of A+++ 14kw R32 Tap Hot Water Geyser Boiler Room Heating Evi Air to Water Heat Pump All in One Water Heater System
EVI Air to water heat pump (Heating and cooling, monoblock type) |
|
Model |
MG-03KFXLR |
MG-03KFXLR |
MG-05KFXLR |
MG-05KFXLR/380V |
MG-10KFXLR |
MG-20KFXLR |
Specifications |
Input power |
Heating mode |
KW |
2.03 |
2.29 |
3.49 |
4.09 |
8.24 |
14.2 |
Heating capacity |
KW |
8.1 |
9.1 |
14 |
16.4 |
32.8 |
57.2 |
COP |
|
3.99 |
3.97 |
4.01 |
4.01 |
3.98 |
4.03 |
Current |
A |
10.2 |
4.5 |
15.9 |
7.5 |
14.5 |
26 |
Water flow |
L/h |
2000 |
2200 |
3408 |
4000 |
8000 |
13800 |
Input power |
Cooling mode |
KW |
2.32 |
2.62 |
4.01 |
4.71 |
9.42 |
15.9 |
Cooling capacity |
KW |
6.3 |
7.1 |
11 |
12.8 |
25.6 |
43.8 |
EER |
|
2.72 |
2.71 |
2.74 |
2.72 |
2.72 |
2.75 |
Current |
A |
10.70 |
4.80 |
12.50 |
8.00 |
16.00 |
28.00 |
Water flow |
L/h |
1400 |
1600 |
2386 |
2800 |
5600 |
10200 |
Water pressure drop |
Kpa |
≥70 |
≥70 |
≥70 |
≥70 |
≥80 |
≥70 |
Level of protection |
IPX4 |
IPX4 |
IPX4 |
IPX4 |
IPX4 |
IPX4 |
Electric shock proof grade |
I |
I |
I |
I |
I |
I |
Noise in 1M |
db(A) |
50 |
50 |
60 |
60 |
65 |
75 |
Net weight |
kg |
120 |
120 |
160 |
160 |
280 |
771.5 |
Gross weight |
kg |
130.5 |
130.5 |
175 |
175 |
303 |
875 |
Pipe size |
mm |
25 |
25 |
25 |
25 |
32 |
50 |
Standard components |
Power supply |
V |
220V~240V |
380V~415V |
220V~240V |
380V~415V |
380V~415V |
380V~415V |
Power supply L wire line |
Mm2 |
2.5 |
2.5 |
4 |
4 |
6 |
10 |
Power supply N wire line |
Mm2 |
|
1.5 |
2.5 |
2.5 |
2.5 |
4 |
Dimension |
mm |
830*490*1160 |
1090*480*1260 |
1450*740*1150 |
1850*1000*1950 |
Packing dimension |
mm |
1160*500*1410 |
1510*820*1320 |
1940*1120*2180 |
Compressor model/ quantity |
|
ZW30KSE*1 |
ZW34KSE*1 |
ZW52KSE*1 |
ZW61KSE*1 |
ZW61KSE*2 |
ZW108KSE*2 |
Compressor |
Copeland scroll compressor |
Load side heat exchanger |
Double-pipe |
Tube in shell |
Source side |
Blue hydrophilic aliuminium foil,wavy fin and copper tube heat exchanger |
4-way valve |
SHF-11-45D1*1 |
SHF-20A-46*1 |
2*SHF-20A-46*2 |
2*SHF-35A-79*2 |
Thermal expansion valve |
Emerson 3Ton |
Emerson 5Ton |
Emerson 5Ton*2 |
Emerson 10Ton*2 |
Fan motor |
|
90W*1 |
90W*1 |
90W*2 |
90W*2 |
250W*2 |
800W*2 |
Cabinet |
|
Galvanized sheet/ Spray coating / gray color |
Controller |
|
multiple function controller |
High pressure switch |
|
3.0/3.4MPa |
Low pressure switch |
|
0.15/0.32MPa |
Working mode |
|
heating mode, cooling mode, hot water mode, heating + hot water, cooling + hot water |
Package |
|
Polywood case |
Refrigerant |
|
R32/R407C |
Remarks: |
Working air temperature range:MG-03KFXLR and MG-10KFXLR:-25ºC to 43ºC; MG-20KFXLR:-20ºC to 43ºC |
Rated working condition: Heating: air temperature (DB/WB): 7ºC/6ºC, water temp. (inlet/outlet):40ºC/45ºC; Cooling: air temp. (DB/WB): 35ºC, wet-bulb temp: 24ºC, water temperature (inlet/outlet):12ºC/7ºC; Hot water:dry-bulb temp: 20ºC, wet-bulb temp: 15ºC, cool water temp: 15ºC, hot water temp:55 ºC. |
Image Detail of A+++ 14kw Tap Hot Water Geyser Boiler Room Heating Evi Air to Water Heat Pump All in One Water Heater System
Operate Principle of A+++ 14kw R32 Tap Hot Water Geyser Boiler Room Heating Evi Air to Water Heat Pump All in One Water Heater System
Certificates of A+++ 14kw R32 Tap Hot Water Geyser Boiler Room Heating Evi Air to Water Heat Pump All in One Water Heater System
Application of A+++ 14kw R32 Tap Hot Water Geyser Boiler Room Heating Evi Air to Water Heat Pump All in One Water Heater System
Comment by return on A+++ 14kw R32 Tap Hot Water Geyser Boiler Room Heating Evi Air to Water Heat Pump All in One Water Heater System
Sent an inquiry to get export subsidies QUOTA on A+++ 14kw R32 Tap Hot Water Geyser Boiler Room Heating Evi Air to Water Heat Pump All in One Water Heater System