Geothermal ground source heat pump,240KW,Cooling and heating function
MANGO Ground / Water source heat pump is the best choice for places where hot water is in demand such as private houses,villas, restaurants, hotels, beauty salons, fitness centers, SPA and massage centers, public baths, hospitals,dormitories,aquaculture farms, etc.
With outstanding features of high efficient and energy-saving, safe and reliable,environmental-friendly and comfortable, low operation costs, etc, it is a direct replacements for traditional hot water devices like coal, oil and gas boilers.
*50Hz/60Hz Ultra SCOP5.0 40KW Home Heating 32KW Air Chilling Outlet R32 Ground Water Source Heat Pump Water Chiller
1. SCOP ≥4.8, Energy-saving 80%;
2. Durability, the longest service time, exceeding 5-8 years;
3. R32/R410A green refrigerant;
4. Ultra USA Copeland Scroll compressor;
5. WIFI, free of distance operation;
6. Multi-function, house heating in winter, air cooling summer, or 4-season domestic hot water
7. Super low noise in door;
8. Wide power range: 380-415V /60Hz/3ph.
Specification
Model |
MG-03SFXLN |
MG-03SFXLN/380 |
MG-045SFXLN |
MG-05SFXLN |
MG-06SFXLN |
Heating capicity(W15/W45) |
kw |
11 |
12 |
19 |
20 |
24 |
Input power |
kw |
2.36 |
2.58 |
4.10 |
4.32 |
5.22 |
Current |
A |
11.3 |
5.4 |
19.6 |
9.1 |
11.0 |
COP |
|
4.66 |
4.65 |
4.63 |
4.63 |
4.60 |
Cooling capicity(W35/W7) |
kw |
8.8 |
9.6 |
15.2 |
16 |
19.2 |
Input power |
kw |
2.05 |
2.24 |
3.57 |
3.76 |
4.54 |
Current |
A |
9.8 |
4.7 |
17.1 |
7.9 |
9.6 |
EER |
|
4.29 |
4.28 |
4.26 |
4.26 |
4.23 |
Voltage |
V/Hz |
|
380~415/50/3 |
220~240/50/1 |
380~415/50/3 |
Rated/Max water temp |
45~55°C for heating, 7~12 °C for cooling. |
Water flow |
m3/H |
2.4 |
2.6 |
4.1 |
4.3 |
5.2 |
Refrigeration |
|
R410A |
Source side temperature |
(-5ºC -- 45ºC) |
Dimension |
mm |
710*520*1000 |
710*520*1000 |
710*520*1000 |
710*520*1000 |
710*520*1000 |
Model |
MG-07SFXLN |
MG-10SFXLN |
MG-12SFXLN |
MG-15SFXLN |
MG-20SFXLN |
MG-25SFXLN |
Heating capicity (W15/W45) |
kw |
28 |
40 |
48 |
58 |
80 |
100 |
Input power |
kw |
6.09 |
8.53 |
10.30 |
12.29 |
16.91 |
21.14 |
Current |
A |
12.8 |
18.0 |
21.7 |
25.9 |
35.7 |
44.6 |
COP |
|
4.60 |
4.69 |
4.66 |
4.72 |
4.73 |
4.73 |
Cooling capicity (A35/W7) |
kw |
22.4 |
32 |
38.4 |
46.4 |
64 |
80 |
Input power |
kw |
5.29 |
7.42 |
8.96 |
10.69 |
14.71 |
18.38 |
Current |
A |
11.2 |
15.7 |
18.9 |
22.5 |
31.0 |
38.8 |
EER |
|
4.23 |
4.31 |
4.29 |
4.34 |
4.35 |
4.35 |
Voltage |
V/Hz |
380~415/50/3 |
Rated/Max water temp |
45~55°C for heating, 7~12 °C for cooling. |
Water flow |
m3/H |
6.0 |
8.6 |
10.3 |
12.5 |
17.2 |
21.5 |
Water pressure drop |
kPa |
≤65 |
≤60 |
≤68 |
≤70 |
≤75 |
≤85 |
Refrigeration |
|
R410A |
Compressor(Copeland Scroll) |
ZW79KAE*1 |
ZW61KAE*2 |
ZW72KAE*2 |
ZW79KAE*2 |
ZW108KAE*2 |
VR144KSE*2 |
Condenser |
High efficient tank heat exchanger / Shell and tube heat exchanger |
Evaporator |
Stainless steel Plate heat exchanger |
A/C contactor&Thermal relay |
Korea LS |
Throttle unit |
|
|
Controller |
|
Microcomputer central processor (LCD wire controller) |
Source side temperature |
(-5ºC -- 45ºC) |
Water pipe size |
|
DN25 |
DN40 |
DN40 |
DN40 |
DN50 |
DN65 |
Noise |
|
≤52 |
≤58 |
≤58 |
≤58 |
≤62 |
≤62 |
Dimension |
mm |
710*520*1000 |
1280*830*800 |
1280*830*800 |
1320*840*1130 |
1750*1120*1160 |
1750*1120*1160 |
Weight (N./W.) |
kg |
135/145 |
280/300 |
320/340 |
372/395 |
560/588 |
582/615 |
Heating test conditions: Source side inlet/outlet water temp: 15ºC/10ºC,load side inlet/outlet water temp:40ºC/45ºC. |
Cooling test conditions: Source side inlet/outlet water temp: 35ºC/30ºC,load side inlet/outlet water temp:12ºC/7ºC. |
Model |
MG-300KFXLN |
MG-400KFXLN |
MG-500KFXLN |
MG-600KFXLN |
Heating capicity (A7/W45) |
kw |
120 |
160 |
200 |
240 |
Input power |
kw |
25.37 |
33.83 |
42.28 |
50.74 |
Current |
A |
53.5 |
64.2 |
80.3 |
96.4 |
COP |
|
4.73 |
4.73 |
4.73 |
4.73 |
Cooling capicity (A35/W7) |
kw |
96.0 |
128.0 |
160.0 |
192.0 |
Input power |
kw |
22.06 |
29.41 |
36.77 |
44.12 |
Current |
A |
46.6 |
62.1 |
77.6 |
93.1 |
EER |
|
4.35 |
4.35 |
4.35 |
4.35 |
Voltage |
V/Hz |
380~415/50/3 |
Rated/Max water temp |
45~55°C for heating, 7~12 °C for cooling. |
Water flow |
m3/H |
25.8 |
34.4 |
43.0 |
51.6 |
Water pressure drop |
kPa |
≤86 |
≤87 |
≤88 |
≤90 |
Refrigeration |
|
R410A |
Compressor(Copeland Scroll) |
ZW108KAE*3 |
ZW108KAE*4 |
VR144KSE*4 |
ZR190KCE*4 |
Condenser |
Tube-in Shell heat exchanger |
Evaporator |
Tube-in Shell /Plate heat exchanger |
A/C contactor&Thermal relay |
Korea LS |
Throttle unit |
|
|
Controller |
|
Microcomputer central processor (LCD wire controller) |
Source side temperature |
(-5ºC -- 45ºC) |
Water pipe size |
|
DN65 |
DN80 |
DN80 |
DN80 |
Noise |
|
≤65 |
≤65 |
≤65 |
≤65 |
Dimension |
mm |
2000*1120*1160 |
2200*1500*1200 |
2200*1500*1200 |
2200*1500*1200 |
Weight (N./W.) |
kg |
680/720 |
900/945 |
1050/1100 |
1080/1130 |
Heating test conditions: Source side inlet/outlet water temp: 15ºC/10ºC,load side inlet/outlet water temp:40ºC/45ºC. |
|
|
|
|
|
Cooling test conditions: Source side inlet/outlet water temp: 35ºC/30ºC,load side inlet/outlet water temp:12ºC/7ºC. |
|
|
|
|
|
FAQ : Marketing of Mango Energy.
Q1> What does mango energy company do ?
A1: Mango energy is professional manufacturer of ON/OFF heat pump , DC inverter heat pump, air source heat pump,water to water heat pump , swimming pool heat pump,high temperature heat pump so on all kind of heat pump.
Q2> What is the daily production of Mango energy company ?
A2: Mango energy one day produce heat pump water heater around 150~255 PCS / day.
Q3> What is Mango heat pump certification ?
A3 : Mango energy have : SGS, CE,CB, IEC60335-2-40, EN14511 certificate from TUV Lab,, got ISO9001. ISO18001, ISO14001 and CCC certificate. Get Class A+, A as ErP EN14825 test report .
Q4> Where are the Mango energy heat pump export to till now ?
A4 : Currently the products has been exported to Western Europe, North Europe, South Africa, Middle-East, South American and Australia market.
Q5> What is the marketing cooperation case with Mango energy ?
A5: Mango energy all find exclusive agent / distributor / wholesale / OEM
Mango energy is manufacturer , so we do not directly face to end user / retail ,
After sign sales contract at this district , we will do not sales to others buyers again,
So agent / distributor care for this district sales & service .
Q6> What Mango energy do for their agent / distributor /OEM ?
A6 : Mango energy offer sales training , heat pump & solar air conditioner product training,
After sales service training , maintenance machine training , big air chiller ,or heating
Project design case training , inside parts exchange training and test training.
Q7> How can get training from Mango energy ?
A7 : If have time , can visit to my factory to training, or invite we engineer team to yours side
Training , or by Video training online.
Q8> What Mango energy offer to their business partner ?
A8: Mango energy offer 1%~2% free spare parts according to order quantity .
Offer whole this district market exclusive sales right .
Offer rebate as this district agent sales amount within one year .
Offer best competitive price & repair parts .
Offer 24 hours online service .
Q9> where is Mango energy heat pump using ?
A9: Because Air source heat pump save energy around 70% , ( EVI heat pump and central cooling & heating heat pump ) is Widely used in home heating, hotels hot water & heating , restaurants, hospitals,schools, bath center, residential central heating and hot water plants, etc.