R32 11kw 50-60Hz Evi Split Type Air to Water Geyser Heater Pump -25DegC Cold Temperature Floor Heating Boiler
Product Description:
1. Top SCOP in cold, ENERGY SAVING in homoeothermy, Copeland / Panasonic / GMCC / Toshiba / Sanyo compressor and ECO R32/R410/R290 refrigerant for max heat capacity and less refrigerant, large volume of latent heat from the air via evaporator in coldest season.
2. Split design, only evaporator & fan outdoor, ensure big enough air flow volum for satisfying heat energy, while super anti-freeze & protect the key part which easily to be frozen and crack key parts to protect well indoor intalling, especially when air temperature below -10DegC with heavy moisture.
3. Enhanced Vapors Injection (EVI) technology: enable heat pump work constantly and steadily at extrem weather condition -35ºC, adopting the most advanced low temperature EVI compressor and related technology.
4. Advanced Operate System, ultra intelligent, especially superior heat dissipation circuit board design, longer service, over 3 time of other brand's, simple click and fully play the characteristics of DC inverter frequency conversion system to achieve overlocking performance.
5. WIFI remote control, free of distance, your warm care always with sweet face!
6. High-tech shock-absorption all copper construction piping, high-accurate completely automatic silver welding, easy maintenance.
7. High-density protective jacket for minimum heat lost, aviation class insulation foam with outstanding sound absorption.
8. Portable compact design, saving room for installation & operation.
9. 60ºC maximum water termp. outlet, available to projects for either house heating in extrem weather condition or 4-season domastic hot water requirement.
Product Specification:
R32 11kw 50-60Hz Evi Split Type Air to Water Geyser Heater Pump -25DegC Cold Temperature Floor Heating Boiler
Model |
#MG-03(FT)/220 |
#MG-03(FT)/380 |
#MG-05(FT) |
#MG-10(FT) |
Standard components |
Cabinet/color |
Spray coating |
Refrigerant |
R32/R407C/R290 |
Power supply |
220V~240V/50Hz/1ph |
380V~415V/50Hz/3ph |
Compressor |
Copeland EVI compressor |
Condenser |
High efficiency shell and tube heat exchanger |
Economy unit |
Plate heat exchanger |
Evaporator |
Blue hydrophilic aliuminium foil,wavy fin and copper tube heat exchanger |
Throttle unit |
Heat expansion valve |
A/C contactor |
Fuji |
Thermal relay |
Fuji |
Controller |
Muti-function controller |
Low pressure switch |
0.05/0.15MPa |
High pressure switch |
3.0/3.2MPa |
Connect pipe size of gas |
mm |
φ12.7/φ19 |
φ12.7/φ19 |
φ12.7/φ19 |
φ12.7*2/φ19*2 |
Power supply line size |
2.5mm2 |
2.5mm2 |
4mm2 |
6mm2 |
Indoor unit quantity |
PCS |
1 |
1 |
1 |
1 |
Outdoor unit quantity |
PCS |
1 |
1 |
1 |
2 |
Indoor unit packing dimension |
L*W*H |
740*485*1050 |
740*485*1050 |
740*485*1050 |
1040*580*1350 |
Outdoor unit packing dimension |
910*410*860 |
910*410*860 |
1010*490*1420 |
1010*490*1420 |
Specifications |
Heating capacity |
20ºC |
kW |
10.8 |
11.8 |
20.6 |
37.2 |
Input power when heating |
kW |
2.81 |
3.1 |
5.4 |
9.8 |
Rated current |
A |
12.4 |
5.9 |
9 |
17.6 |
COP |
|
3.84 |
3.81 |
3.81 |
3.80 |
Hot water capacity |
L/H |
232 |
254 |
443 |
800 |
Heating capacity |
-10ºC |
kW |
6.3 |
7 |
12.6 |
21.6 |
Input power when heating |
kW |
2.58 |
2.9 |
5.1 |
8.7 |
COP |
|
2.44 |
2.41 |
2.47 |
2.48 |
Hot water capacity |
L/H |
135 |
150 |
271 |
464 |
Heating capacity |
-20ºC |
kW |
4.9 |
5.4 |
10.3 |
15.5 |
Input power when heating |
kW |
2.45 |
2.68 |
5.05 |
7.68 |
COP |
|
2.00 |
2.01 |
2.04 |
2.02 |
Hot water capacity |
L/H |
105 |
116 |
221 |
333 |
Rated outlet water temp |
ºC |
55 |
Max outlet water temp |
ºC |
60 |
Water flow |
m3/H |
2415 |
2638 |
4606 |
8318 |
Level of protection |
|
IPX4 |
IPX4 |
IPX4 |
IPX4 |
Electric shock proof grade |
|
I |
I |
I |
I |
Noise |
dB(A) |
≤55 |
≤55 |
≤60 |
≤60 |
Indoor unit net weight |
kg |
85 |
85 |
125 |
240 |
Outdoor unit net weight |
35 |
35 |
45 |
45*2 |
Indoor unit gross weight |
kg |
90 |
90 |
130 |
247 |
Outdoor unit gross weight |
40 |
40 |
50 |
50*2 |
Indoor unit dimention |
|
L*W*H |
660*385*900 |
660*385*900 |
660*385*900 |
960*480*1200 |
Outdoor unit dimension |
|
830*310*710 |
830*310*710 |
930*390*1270 |
930*390*1270 |
Pipe size |
mm |
DN25 |
DN25 |
DN25 |
DN32 |
Working mode |
|
Heating |
Product Images:
#MG-03(FT)/220 |
#MG-03(FT)/380 |
More Options of R32 11kw 50-60Hz Evi Split Type Air to Water Geyser Heater Pump -25DegC Cold Temperature Floor Heating Boiler
Key Parts of R32 11kw 50-60Hz Evi Split Type Air to Water Geyser Heater Pump -25DegC Cold Temperature Floor Heating Boiler
Application of R32 11kw 50-60Hz Evi Split Type Air to Water Geyser Heater Pump -25DegC Cold Temperature Floor Heating Boiler
R32 11kw 50-60Hz Evi Split Type Air to Water Geyser Heater Pump -25DegC Cold Temperature Floor Heating Boiler is available to compatible with DC Inverter.Send an inquiry right away!!! For more detail of R32 11kw 50-60Hz Evi Split Type Air to Water Geyser Heater Pump -25DegC Cold Temperature Floor Heating Boiler.