• R32 11kw 50-60Hz Evi Split Type Air to Water Geyser Heater Pump -25degc Cold Temperature Floor Heating Boiler
  • R32 11kw 50-60Hz Evi Split Type Air to Water Geyser Heater Pump -25degc Cold Temperature Floor Heating Boiler
  • R32 11kw 50-60Hz Evi Split Type Air to Water Geyser Heater Pump -25degc Cold Temperature Floor Heating Boiler
  • R32 11kw 50-60Hz Evi Split Type Air to Water Geyser Heater Pump -25degc Cold Temperature Floor Heating Boiler
  • R32 11kw 50-60Hz Evi Split Type Air to Water Geyser Heater Pump -25degc Cold Temperature Floor Heating Boiler
  • R32 11kw 50-60Hz Evi Split Type Air to Water Geyser Heater Pump -25degc Cold Temperature Floor Heating Boiler

R32 11kw 50-60Hz Evi Split Type Air to Water Geyser Heater Pump -25degc Cold Temperature Floor Heating Boiler

Energy Efficiency Grade: One
Heat Temperature: 50-70°C
Work Environment: Low-temperature Heat Pump
Samples:
US$ 2160/Piece 1 Piece(Min.Order)
| Order Sample
Existed color housing
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
R32 11kw 50-60Hz Evi Split Type Air to Water Geyser Heater Pump -25degc Cold Temperature Floor Heating Boiler pictures & photos
R32 11kw 50-60Hz Evi Split Type Air to Water Geyser Heater Pump -25degc Cold Temperature Floor Heating Boiler
US $1,899-2,150 / Piece
Min. Order: 1 Piece
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2016

Suppliers with verified business licenses

Secured Trading Service
Guangdong, China
Importers and Exporters
The supplier has import and export rights
Experienced Team
The supplier has 10 foreign trading staff(s) and 6 staff(s) with over 6 years of overseas trading experience
Self-branded
The supplier has 5 Self-brands, check the Audit Report for more information
Low MOQ
The MOQ for the supplier's products is 1
to see all verified strength labels (24)

Basic Info.

Model NO.
MG-03(FT)/220
Heat Source
Air-source
Heating Type
Circulating Heat
Application
Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Certification
CE, ISO9001, CCC, CB, UL, SASO, CSA
Heat Pump
Splite Evi Air to Water Heat Pump
Air Source Heat Pump
Heat Pump
Transport Package
Polywood
Trademark
MANGO
Origin
China
HS Code
8418612090
Production Capacity
30000 Units

Packaging & Delivery

Package Size
1590.00cm * 780.00cm * 1270.00cm
Package Gross Weight
210.000kg

Product Description

R32 11kw 50-60Hz Evi Split Type Air to Water Geyser Heater Pump -25DegC Cold Temperature Floor Heating Boiler
Product Description:
R32 11kw 50-60Hz Evi Split Type Air to Water Geyser Heater Pump -25degc Cold Temperature Floor Heating Boiler
1. Top SCOP in cold, ENERGY SAVING in homoeothermy, Copeland / Panasonic / GMCC / Toshiba / Sanyo compressor and ECO R32/R410/R290 refrigerant for max heat capacity and less refrigerant, large volume of latent heat from the air via evaporator in coldest season.
2. Split design, only evaporator & fan outdoor, ensure big enough air flow volum for satisfying heat energy, while super anti-freeze & protect the key part which easily to be frozen and crack key parts to protect well indoor intalling, especially when air temperature below -10DegC with heavy moisture.

3. Enhanced Vapors Injection (EVI) technology: enable heat pump work constantly and steadily at extrem weather condition -35ºC, adopting the most advanced low temperature EVI compressor and related technology.

4. Advanced Operate System, ultra intelligent, especially superior heat dissipation circuit board design, longer service, over 3 time of other brand's, simple click and fully play the characteristics of DC inverter frequency conversion system to achieve overlocking performance.
5. WIFI remote control, free of distance, your warm care always with sweet face!
6. High-tech shock-absorption all copper construction piping, high-accurate completely automatic silver welding, easy maintenance.
7. High-density protective jacket for minimum heat lost, aviation class insulation foam with outstanding sound absorption.
8. Portable compact design, saving room for installation & operation.

9. 60ºC maximum water termp. outlet, available to projects for either house heating in extrem weather condition or 4-season domastic hot water requirement.
R32 11kw 50-60Hz Evi Split Type Air to Water Geyser Heater Pump -25degc Cold Temperature Floor Heating Boiler
Product Specification:
R32 11kw 50-60Hz Evi Split Type Air to Water Geyser Heater Pump -25DegC Cold Temperature Floor Heating Boiler
Model #MG-03(FT)/220 #MG-03(FT)/380 #MG-05(FT) #MG-10(FT)
Standard components Cabinet/color Spray coating
Refrigerant R32/R407C/R290
Power supply 220V~240V/50Hz/1ph 380V~415V/50Hz/3ph
Compressor Copeland EVI compressor
Condenser High efficiency shell and tube heat exchanger
Economy unit Plate heat exchanger
Evaporator Blue hydrophilic aliuminium foil,wavy fin  and copper tube heat exchanger
Throttle unit Heat expansion valve
A/C contactor Fuji
Thermal relay Fuji
Controller Muti-function controller
Low pressure switch 0.05/0.15MPa 
High pressure switch 3.0/3.2MPa
Connect pipe size of gas mm φ12.7/φ19 φ12.7/φ19 φ12.7/φ19 φ12.7*2/φ19*2
Power supply line size 2.5mm2 2.5mm2 4mm2 6mm2
Indoor unit quantity PCS 1 1 1 1
Outdoor unit quantity PCS 1 1 1 2
Indoor unit packing dimension L*W*H 740*485*1050 740*485*1050 740*485*1050 1040*580*1350
Outdoor unit packing dimension 910*410*860 910*410*860 1010*490*1420 1010*490*1420
Specifications Heating capacity  20ºC kW 10.8 11.8 20.6 37.2
Input power when heating kW 2.81 3.1 5.4 9.8
Rated current A 12.4 5.9 9 17.6
COP   3.84 3.81 3.81 3.80
Hot water capacity L/H 232 254 443 800
Heating capacity  -10ºC kW 6.3 7 12.6 21.6
Input power when heating kW 2.58 2.9 5.1 8.7
COP   2.44 2.41 2.47 2.48
Hot water capacity L/H 135 150 271 464
Heating capacity  -20ºC kW 4.9 5.4 10.3 15.5
Input power when heating kW 2.45 2.68 5.05 7.68
COP   2.00 2.01 2.04 2.02
Hot water capacity L/H 105 116 221 333
Rated outlet water temp ºC 55
Max outlet water temp ºC 60
Water flow m3/H 2415 2638 4606 8318
Level of protection   IPX4 IPX4 IPX4 IPX4
Electric shock proof grade   I I I I
Noise dB(A) ≤55 ≤55 ≤60 ≤60
Indoor unit net weight kg 85 85 125 240
Outdoor unit net weight 35 35 45 45*2
Indoor unit gross weight kg 90 90 130 247
Outdoor unit gross weight 40 40 50 50*2
Indoor unit dimention   L*W*H 660*385*900 660*385*900 660*385*900 960*480*1200
Outdoor unit dimension   830*310*710 830*310*710 930*390*1270 930*390*1270
Pipe size mm DN25 DN25 DN25 DN32
Working mode   Heating
Product Images:
#MG-03(FT)/220 #MG-03(FT)/380

R32 11kw 50-60Hz Evi Split Type Air to Water Geyser Heater Pump -25degc Cold Temperature Floor Heating Boiler
#MG-05(FT) #MG-10(FT)
R32 11kw 50-60Hz Evi Split Type Air to Water Geyser Heater Pump -25degc Cold Temperature Floor Heating BoilerMore Options of R32 11kw 50-60Hz Evi Split Type Air to Water Geyser Heater Pump -25DegC Cold Temperature Floor Heating Boiler
R32 11kw 50-60Hz Evi Split Type Air to Water Geyser Heater Pump -25degc Cold Temperature Floor Heating BoilerR32 11kw 50-60Hz Evi Split Type Air to Water Geyser Heater Pump -25degc Cold Temperature Floor Heating Boiler
Key Parts of R32 11kw 50-60Hz Evi Split Type Air to Water Geyser Heater Pump -25DegC Cold Temperature Floor Heating Boiler
R32 11kw 50-60Hz Evi Split Type Air to Water Geyser Heater Pump -25degc Cold Temperature Floor Heating Boiler

R32 11kw 50-60Hz Evi Split Type Air to Water Geyser Heater Pump -25degc Cold Temperature Floor Heating BoilerR32 11kw 50-60Hz Evi Split Type Air to Water Geyser Heater Pump -25degc Cold Temperature Floor Heating BoilerApplication of R32 11kw 50-60Hz Evi Split Type Air to Water Geyser Heater Pump -25DegC Cold Temperature Floor Heating Boiler
R32 11kw 50-60Hz Evi Split Type Air to Water Geyser Heater Pump -25degc Cold Temperature Floor Heating BoilerR32 11kw 50-60Hz Evi Split Type Air to Water Geyser Heater Pump -25DegC Cold Temperature Floor Heating Boiler is available to compatible with DC Inverter.R32 11kw 50-60Hz Evi Split Type Air to Water Geyser Heater Pump -25degc Cold Temperature Floor Heating BoilerSend an inquiry right away!!! For more detail of R32 11kw 50-60Hz Evi Split Type Air to Water Geyser Heater Pump -25DegC Cold Temperature Floor Heating Boiler.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
R32 11kw 50-60Hz Evi Split Type Air to Water Geyser Heater Pump -25degc Cold Temperature Floor Heating Boiler pictures & photos
R32 11kw 50-60Hz Evi Split Type Air to Water Geyser Heater Pump -25degc Cold Temperature Floor Heating Boiler
US $1,899-2,150 / Piece
Min. Order: 1 Piece
Diamond Member Since 2016

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
Number of Employees
42
Year of Establishment
2015-11-05