Energy Efficiency Grade: | One |
---|---|
Heat Temperature: | 50-70°C |
Work Environment: | Common Heat Pump |
Customization: |
---|
Shipping Cost:
Estimated freight per unit. |
about shipping cost and estimated delivery time. |
---|
Payment Method: | |
---|---|
Initial Payment Full Payment |
Currency: | US$ |
---|
Return&refunds: | You can apply for a refund up to 30 days after receipt of the products. |
---|
Suppliers with verified business licenses
Seeking OEM parter normal air to water heat pump
We do many testing as follows before delivery:
1)Standard heating, cooling
2)Simulate Low and High temp working condition, a variety of ambient temp, indoor temp and outdoor temp.
3)Power consumption
4)COP and SEER
5)Defrosting
6)Air conditioner, water source, air source and hot water heat pump performance and capacity reliability testing
7)Controller function testing
8)Test goods at all kinds of power supply
9)Setting Temp ranges -10~55ºC, its accuracy is +-0.2ºC; Humidity ranges 20%~99%, its accuracy is +-1%.
10) DC inverter water flow and air flow control (100m³/h ~ 3000 m³/h)
11) Temp, pressure, power collector
Model No. | Unit | MG-030KFXRS | MG-050KFXRS | MG-080KFXRS | MG-100KFXRS | MG-120KFXRS | MG-200KFXRS | MG-250KFXRS | ||||
Heating Capacity | KW | 10.8 | 18 | 28.8 | 38 | 43.2 | 72 | 86.4 | ||||
Power Input | KW | 2.7 | 4.5 | 7.2 | 9.6 | 10.8 | 18 | 21.6 | ||||
Largest Current | A | 5.9 | 5.9 | 9 | 11.2 | 17.6 | 36.1 | 41.4 | ||||
Rated Water Temp. | ºC | 55 | 55 | 55 | 55 | 55 | 55 | 55 | ||||
Highest Water Temp. | ºC | 60 | 60 | 60 | 60 | 60 | 60 | 60 | ||||
Power Supply | 220V/1P/50Hz | 380V/3P/50Hz | ||||||||||
Anti-electric Shock Type | ||||||||||||
Compressor | Scroll | |||||||||||
Compressor brand | Copeland | |||||||||||
Quantity of Compressor | 1 | 1 | 2 | 2 | 4 | 4 | ||||||
Fan Direction | Discharge | Vertical | ||||||||||
Quantity of Fan | 1 | 1 | 2 | 2 | 3 | 3 | ||||||
Refrigerant | R417A | |||||||||||
Ambient temp. | ºC | -10-45 | -10-45 | -10-45 | -10-45 | -10-45 | -10-45 | -10-45 | ||||
Hot Water Supply | L/H | 267 | 400 | 620 | 817 | 928 | 1548 | 1856 | ||||
Pipe Size | Inch | 1″ | 1″ | 1 1/4″ | 1 1/4″ | 2 1/2″ | 2 1/2″ | |||||
Circulation of Water Capacity | M3/h | 3 | 5 | 8 | 10 | 12 | 20 | 24 | ||||
Pressure from Tap Water | kPa | 46 | 46 | 46 | 46 | 46 | 46 | 46 | ||||
Noise | dBA | <=54 | <=56 | <=60 | <=60 | <=60 | <=62 | <=62 | ||||
Mainframe Weight | kg | 100 | 180 | 340 | 360 | 380 | 680 | 760 | ||||
Dimension(mm) | Length | 810 | 1110 | 1500 | 1500 | 1430 | 2170 | 2170 | ||||
Width | 691 | 490 | 800 | 800 | 780 | 1065 | 1065 | |||||
Height | 870 | 1260 | 1600 | 1600 | 1376 | 1890 | 1890 | |||||
Running conditions: Ambient temperature DB(dry bulb) 20 ºC, WB(wet bulb)15ºC, Inlet water temp:15ºC, Outlet water temp:55ºC. |
Suppliers with verified business licenses