Customization: | Available |
---|---|
Energy Efficiency Grade: | One |
Heat Temperature: | 55degree ~ 60 Degree |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Name | QI Series DC Inverter Heat Pump |
Heating Capacity | 9-34kW |
COP | 2.5-5.6 |
Warranty | 5 Years Full Unit |
MOQ | 1 UNIT |
Q I Series Monoblock DC Inverter Heat Pump Heating | Cooling | Hot Water |
|||||||||
Model | MGSDC-030IIC | MGSDC-050IIC | MGSDC-060IIC | MGSDC-080IIC | MGSDC-100IIC | ||||
EXW Unit Price(USD) | $1,650.00 | $1,950.00 | $2,300.00 | $2,600.00 | $2,950.00 | ||||
HP | 3HP | 5HP | 6HP | 8HP | 10HP | ||||
Ambient | Outlet | Power Supply | 220-240V / 50-60Hz / 1ph or 380-415V / 50-60Hz / 3ph | 380-415V / 50-60Hz / 3ph | |||||
+20°C | 15-55°C | Heating Capacity | kW | 11 | 20 | 24 | 30 | 34 | |
Power Input | kW | 2 | 3.57 | 4.31 | 5.5 | 6.66 | |||
COP | 5.5 | 5.6 | 5.56 | 5.45 | 5.1 | ||||
+7°C | 35°C | Heating Capacity | kW | 9 | 14 | 16 | 24 | 30 | |
Power Input | kW | 2 | 3.04 | 3.5 | 5.4 | 7.3 | |||
COP | 4.5 | 4.6 | 4.56 | 4.45 | 4.1 | ||||
+7°C | 9-55°C | Heating Capacity | kW | 9 | 14 | 16 | 24 | 28 | |
Power Input | kW | 2.78 | 4.35 | 5.03 | 7.55 | 8.8 | |||
-12°C | 40°C | Heating Capacity | kW | 6 | 10.5 | 11.5 | 17.8 | 22 | |
Power Input | kW | 2.6 | 4.5 | 5.1 | 7.74 | 9.6 | |||
COP | 2.3 | 2.36 | 2.26 | 2.3 | 2.3 | ||||
Heating Operate Range |
Ambient | °C | -30~25 | ||||||
Heating Side | °C | 18~60 | |||||||
Hot Water Operate Range |
Ambient | °C | -30 ~ 35 | ||||||
Water Side | °C | 25~60 | |||||||
+35°C | 7°C | Cooling outlet | kW | 7 | 11 | 13 | 20 | 24 | |
Power Input | kW | 2.6 | 3.95 | 4.81 | 7.25 | 9.2 | |||
EER | 2.7 | 2.8 | 2.7 | 2.76 | 2.6 | ||||
Maximum Working Pressure | Bar | 44 Bar | |||||||
Compressor | - | Panasonic DC Inverter Compressor with EVI System | |||||||
Refrigerant | - | R32 | |||||||
Fan Motor | - | Nidec DC Brushless Motor | |||||||
Controller | - | Touchscreen LCD Controller with WIFI and 13 Languages | |||||||
Water Heating Exchanger | - | SUS 316 Brazed Plate Heat Exchanger | |||||||
External Cabinet | - | 1.5MM Galvanized Steel With Powder Coating | |||||||
EEV | - | "DUNAN" EEV | |||||||
Certificates | - | CE | FCC | UKCA | ISO |
ERP A+++ | |||
Outdoor Air Flow | m3 / h | 2600 | 5600 | 5600 | 7800 | 7800 | |||
Water Flow (Built in Pump) | m3 / h | >1.6 | >3.1 | >3.1 | >3.4 | >3.4 | |||
Expansion Tank | L | 2L | |||||||
Water Pipe | inch | 1" | 1" | 1" | 1-1 / 4" | 1-1 / 4" | |||
Noise in 1M | dB(A) | ≤50 | ≤56 | ≤57 | ≤59 | ≤60 | |||
Unit size | mm | 925*375*770 | 1050*400*1350 | 1175*400*1482 | |||||
Net Weight / Gross Weight | Kg | 76 / 85 | 120 / 146 | 125 / 151 | 165 / 194 | 175 / 212 | |||
Remark | - |
Q I Series Split Type DC Inverter Heat Pump Heating | Cooling | Hot Water |
||||||||
Model | MGSDC-030IIC | MGSDC-050IIC | MGSDC-060IIC | MGSDC-080IIC | MGSDC-100IIC | |||
HP | 3HP | 5HP | 6HP | 8HP | 10HP | |||
Power Supply | Indoor Unit | V/Hz/Ph | 220-240V / 50hz / 1ph or 380-415V / 50Hz / 3ph | |||||
Ambient | Outlet | Outdoor Unit | V/Hz/Ph | 220-240V / 50hz / 1ph or 380-415V / 50Hz / 3ph | 380-415V / 50Hz / 3ph | |||
+7°C | 45°C | Heating Capacity | kW | 9.51 | 16.33 | 19.70 | 24.90 | 30.70 |
Power Input | kW | 2.63 | 4.50 | 5.46 | 6.97 | 8.67 | ||
COP | 3.61 | 3.63 | 3.61 | 3.57 | 3.54 | |||
-12°C | 41°C | Heating Capacity | kW | 6.76 | 11.35 | 13.36 | 16.40 | 20.52 |
Power Input | kW | 2.67 | 4.50 | 5.30 | 6.56 | 8.18 | ||
COP | 2.53 | 2.52 | 2.52 | 2.50 | 2.51 | |||
-20°C | 41°C | Heating Capacity | kW | 5.68 | 9.41 | 11.68 | 14.32 | 17.24 |
Power Input | kW | 2.59 | 4.32 | 5.33 | 6.60 | 8.02 | ||
COP | 2.19 | 2.18 | 2.19 | 2.17 | 2.15 | |||
-35°C | 41°C | Heating Capacity | kW | 3.52 | 5.83 | 7.62 | 8.88 | 10.85 |
Power Input | kW | 2.55 | 4.19 | 5.48 | 6.48 | 7.86 | ||
COP | 1.38 | 1.39 | 1.39 | 1.37 | 1.38 | |||
+35°C | 7°C | Cooling outlet | kW | 7.51 | 13.10 | 16.11 | 20.38 | 23.59 |
Power Input | kW | 2.59 | 4.50 | 5.57 | 7.15 | 8.28 | ||
EER | 2.90 | 2.91 | 2.89 | 2.85 | 2.85 | |||
Compressor | - | Panasonic Twin Roter DC Inverter Compressor with EVI System | ||||||
Refrigerant | - | R32 | ||||||
Fan Motor | - | Nidec DC Brushless Motor | ||||||
Controller | - | Touchscreen LCD Controller with WIFI and 13 Languages | ||||||
Water Heating Exchanger | - | Cooper Brazed Plate Heat Exchanger | ||||||
External Cabinet | - | 1.5MM Galvanized Steel With Powder Coating | ||||||
EEV | - | Dunan | ||||||
Certificates | - | CE | ERP A++ | |||||
Rated Water Flow Rate | m³/h | 1.5 | 2.4 | 2.8 | 4.1 | 5.2 | ||
Rated Pressure Drop | kPa | 30 | 45 | 45 | 40 | 47 | ||
Max Working Pressure | Refrigerant | Bar | 44 Bar | |||||
Water | Bar | 7 Bar | ||||||
Water Connection | Inlet&Outlet | inch | 1" | 1" | 1" | 1" | 1-1/4" | |
Noise Level | Indoor Unit | dB(A) | 42 | 42 | 42 | 42 | 42 | |
Outdoor Unit | dB(A) | 52 | 56 | 58 | 59 | 61 | ||
Net Dimension W*D*H |
Indoor Unit | mm | 522*296*863.5 | 522*296*863.5 | 522*296*863.5 | 522*296*863.5 | 602*308*880 | |
Outdoor Unit | mm | 950*445*800 | 976*410*1273 | 940*448*1365 | 1150*480*1565 | 1405*590*1626 | ||
Net Weight | Indoor Unit | kg | 55 | 43 | 43 | 55 | 70 | |
Outdoor Unit | kg | 58 | 136 | 136 | 120 | 175 | ||
Remark | 1.The values of heating(cooling) capacity/power input/COP(EER) are based on measurement of EN14511 standard.Usage environment, such as operation of the heat pump, room temperature and controller adjustments, may cause disparities between practically determined and these values; 2.Sound pressure level measured at distance of 1m from the device; 3.For wall-mounted type, the compressor is located in the outdoor unit; |