a+++ High Cop 58kw Extremely Cold -50C Floor Heating Geothermal Tap Hot Water Heater Chinese Industrial Water Source Heat Pump Systems
Product Features:
1) Most Safe: Eliminated all problems of traditional water boiler, seperating all, heat source, electric power, heated/chilled sides.
2) Super Reliable: Service life reaches 15 years, even longer, minimum annual maintenance cost.
3)All-weather Operation: Not being effected by weather, snow or rain, even severe air condition, in summer or winter.
4) Environment Friendly: Neither pollution nor waste discharges during entire operate cycle.
5) Economy: Its running costs 4-5 time less than those of traditional (gas/oil) water boiler he-
ating system.
6) Energy Balance: The working fluid transfers heat energy from water (groundwater/water) to hot water for domestic or industrial use: House heating in winter or 4-season domestic hot water.
7) Modular design: More units connection in 1 system is compatible in our Operate System up to various project requirement.
8) Mute operate noise: Sound-off by aviation soundproof foam and device housing sealed.
9) WIFI or RS485 remote control: Free-of-hand Operate System is available frequently.
Certificates of a+++ High Cop 58kw Extremely Cold -50C Floor Heating Geothermal Tap Hot Water Heater Chinese Industrial Water Source Heat Pump Systems:
Product Specifications of a+++ High Cop 58kw Extremely Cold -50C Floor Heating Geothermal Tap Hot Water Heater Chinese Industrial Water Source Heat Pump Systems:
Water/Geothermal source heat pump (Heating and cooling mode, Monoblock type)
Model |
MG-03SFXLRS/380 |
MG-05SFXLRS |
MG-06SFXLRS |
MG-10SFXLRS |
MG-12SFXLRS |
MG-15SFXLRS |
Specifications |
Heating input power |
Heating mode |
KW |
2.35 |
4.15 |
4.9 |
8.35 |
9.84 |
10.8 |
Heating capacity |
KW |
11.8 |
21.3 |
25.2 |
42.6 |
50.4 |
56.7 |
COP |
|
5.02 |
5.13 |
5.14 |
5.10 |
5.12 |
5.25 |
cooling input power |
Cooling mode |
KW |
1.7 |
3 |
3.4 |
6 |
6.8 |
7.7 |
Cooling capacity |
KW |
7.8 |
14 |
16.5 |
28 |
33 |
37.1 |
EER |
|
4.59 |
4.67 |
4.85 |
4.67 |
4.85 |
4.82 |
pipe size |
mm |
25 |
25 |
25 |
32 |
32 |
50 |
noise in 1M |
db(A) |
50 |
50 |
50 |
50 |
55 |
55 |
net weight |
kg |
90 |
123 |
133 |
286 |
306 |
358 |
gross weight |
kg |
94 |
133 |
143 |
301 |
321 |
378 |
Level of protection |
IPX4 |
IPX4 |
IPX4 |
IPX4 |
IPX4 |
IPX4 |
Electric shock proof level |
I |
I |
I |
I |
I |
I |
Standard components |
cabinet |
Galvanized sheet/ Spray coating / gray color |
Unit size |
mm |
710*520*1000 |
1280*830*800 |
1320*840*1130 |
packing size |
mm |
760*570*1130 |
1330*880*930 |
1410*940*1290 |
Refrigerant |
R32/2.4kg*1 |
R32/3.3kg*1 |
R32/3.6kg*1 |
R32/3.3kg*2 |
R32/3.6kg*2 |
R32/5kg*2 |
Power supply |
380V~415V/50Hz/3ph |
Power supply L wire line |
Mm2 |
2.5 |
4 |
6 |
6 |
6 |
10 |
Power supply N wire line |
Mm2 |
1.5 |
2.5 |
2.5 |
2.5 |
2.5 |
4 |
compressor model |
ZW34KAE |
ZW61KAE |
ZR72KCE |
ZW61KAE |
ZR72KCE |
ZW81KCE |
compressor |
Copeland 1pc |
Copeland 1pc |
Copeland 2pcs |
load side HE |
Double-pipe heat exchanger |
Shell and tube heat exchanger |
source side HE |
Plate heat exchanger |
4-way valve |
SHF-11-45D1*1 |
SHF-20A-46*1 |
SHF-20A-46*1 |
2*SHF-20A-46*2 |
2*SHF-20A-46*2 |
2*SHF-20A-46*2 |
Thermal expansion valve |
Emerson 3Ton |
Emerson 5Ton |
Emerson 6Ton |
Emerson 5Ton*2 |
Emerson 6Ton*2 |
Emerson 7.5Ton*2 |
Controller |
multiple function controller |
Protection function |
Tempreature protection, time protection, water flow protection, antifreeze protection, current protection |
Water pressure switch |
0.015Mpa :OFF, 0.03Mpa: ON |
High pressure switch |
3.0/3.4MPa |
Low pressure switch |
0.15/0.32MPa |
Package |
Plywood case |
working mode |
Heating mode and cooling mode |
|
Remarks: |
|
Exclude: inside water pump, water tank |
|
Working range:source side water inlet temp: 0ºC-40ºC |
Rated Operate Conditions |
Cooling: source side inlet/outlet water temp: 35ºC/30ºC, load side inlet/outlet water temp: 12ºC/7ºC; Heating: source side inlet/outlet water temp:15ºC/10ºC,load side inlet/outlet water temp:50ºC/55ºC; |
Product Images of a+++ High Cop 58kw Extremely Cold -50C Floor Heating Geothermal Tap Hot Water Heater Chinese Industrial Water Source Heat Pump Systems:
Work Principle 01 of a+++ High Cop 58kw Extremely Cold -50C Floor Heating Geothermal Tap Hot Water Heater Chinese Industrial Water Source Heat Pump Systems:
Work Principle 02 of a+++ High Cop 58kw Extremely Cold -50C Floor Heating Geothermal Tap Hot Water Heater Chinese Industrial Water Source Heat Pump Systems:
Operate Principle of a+++ High Cop 58kw Extremely Cold -50C Floor Heating Geothermal Tap Hot Water Heater Chinese Industrial Water Source Heat Pump Systems:
Installation of a+++ High Cop 58kw Extremely Cold -50C Floor Heating Geothermal Tap Hot Water Heater Chinese Industrial Water Source Heat Pump Systems:
Application of a+++ High Cop 58kw Extremely Cold -50C Floor Heating Geothermal Tap Hot Water Heater Chinese Industrial Water Source Heat Pump Systems:
If you are interested in "a+++ High Cop 58kw Extremely Cold -50C Floor Heating Geothermal Tap Hot Water Heater Chinese Industrial Water Source Heat Pump Systems", just send an inquiry to get up to 30% discount for you!!!