Heatpump Air Source Water Heater Heating Pump

Product Details
Customization: Available
Energy Efficiency Grade: One
Heat Temperature: 50-70°C
Still deciding? Get samples of US$ 1000/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2016

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Experienced Team
The supplier has 10 foreign trading staff(s) and 6 staff(s) with over 6 years of overseas trading experience
Self-branded
The supplier has 6 Self-brands, check the Audit Report for more information
Low MOQ
The MOQ for the supplier's products is 1
to see all verified strength labels (24)
  • Heatpump Air Source Water Heater Heating Pump
  • Heatpump Air Source Water Heater Heating Pump
  • Heatpump Air Source Water Heater Heating Pump
Find Similar Products

Basic Info.

Model NO.
MG-10KFXRS
Work Environment
Common Heat Pump
Heat Source
Air-source
Heating Type
Circulating Heat
Application
Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Certification
CE, ISO9001, CCC, CB, RoHS, SASO
City
Guangzhou
Packing
Carton
Noise
58
Evaporator
Stainless Steel Plate Heat Exchanger
Transport Package
Ply Wood
Specification
800*800*925mm
Trademark
Mango
Origin
China
HS Code
8418619000
Production Capacity
5000000000000000000/Years

Packaging & Delivery

Package Size
12.00cm * 8.00cm * 8.00cm
Package Gross Weight
145.000kg

Product Description

2018 CE certificated  heatpump air source water heater heating pump
Feature:

1. Operation range: -7°C~46°C ambient temperature. Running without being effected by weather, even stormy

rain or stormy snow.

2. Power supply: 220V/1ph/50(60)HZ or 380V/3ph/50(60)HZ;

3. The tube in shell or tube in tube heat exchanger are availble;

4. The well-known brand throtting device- Danfoss expansion valve are included, it can control the refrigerant flow  accurately.

5. Adjustable defrosting according to different weather conditions (with 4-way valve inside).

6. Water flow switch is optional.

7. Special design for the fan shroud, with accurate and equal distance between the fan blades and the fan shroud, low vibration, and low noise when running.

8. Compact design and accurate workmanship for fixing the case with bolts and nuts, no damage to the case coating, avoiding corrosion and rust to the case.

9.Multiple protections to protect the compressor and the heat exchanger, like anti-freezing protection, water flow protection, over high pressure protection, over low pressure protection insufficient water flow protection etc;

10.General testing and operational test carried out for every unit to ensure the superior quality and feature before well package at factory.

11. Modular and diversifying design: we can add on more units or design heat pumps according to customer's requirements.

Model No. Unit MG-030KFXRS MG-050KFXRS MG-030KFXRS MG-050KFXRS MG-080KFXRS MG-100KFXRS MG-120KFXRS MG-200KFXRS MG-250KFXRS
Heating Capacity KW 12.1 20.8 12.1 20.8 29.8 39.8 44.3 75 86.4
Power Input KW 2.7 4.5 2.7 4.5 7.2 9.6 10.8 18 21.6
Largest Current A 5.9 5.9 5.9 5.9 9 11.2 17.6 36.1 41.4
Rated Water Temp. ºC 55
Highest Water Temp. ºC 60
Power Supply   220V/1P/50/60Hz 380V50//60Hz
Anti-electric Shock Type     I
Compressor   Scroll
Quantity of Compressor   1 2   2 2 2
Fan Direction Discharge Vertical
Quantity of Fan    1 2   2 2 2
Refrigerant    R22 ,R417A,R410
Ambient temp. ºC -12-48
Hot Water Supply L/H 285 525 285 525 710 998 1250 2020 2365
Circulation of Water Capacity M3/h 3 5 3 5 8 10 12 20 24
Pressure from Tap Water kPa 46 46 46 46 46 46 46 46 46
Noise dBA <=54 <=56 <=54 <=56 <=60 <=60 <=60 <=62 <=62
Mainframe Weight kg 100 180 100 180 340 360 380 680 760
Side fan  Dimension(mm) Length  810 1110 810 1110 1610 1610 1610 2170 2170
Width 691 490 691 490
Height 870 1260 870 1260 900 900 900 1065 1065
Top fan TDimension(mm) Length  800 900 800 900
Width 800 900 800 900 1078 1078 1078 1890 1890
Height 925 1100 925 1100
Heatpump Air Source Water Heater Heating Pump
Heatpump Air Source Water Heater Heating Pump
Heatpump Air Source Water Heater Heating PumpHeatpump Air Source Water Heater Heating PumpHeatpump Air Source Water Heater Heating PumpHeatpump Air Source Water Heater Heating Pump

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Product Groups
More