• CE 11-20kw ERP Test Report 1pH DC Inverter Heat Pump Water Heated High Cop Energy Saving Heating/Cooling/Hot Water Warmepumpe
  • CE 11-20kw ERP Test Report 1pH DC Inverter Heat Pump Water Heated High Cop Energy Saving Heating/Cooling/Hot Water Warmepumpe
  • CE 11-20kw ERP Test Report 1pH DC Inverter Heat Pump Water Heated High Cop Energy Saving Heating/Cooling/Hot Water Warmepumpe
  • CE 11-20kw ERP Test Report 1pH DC Inverter Heat Pump Water Heated High Cop Energy Saving Heating/Cooling/Hot Water Warmepumpe
  • CE 11-20kw ERP Test Report 1pH DC Inverter Heat Pump Water Heated High Cop Energy Saving Heating/Cooling/Hot Water Warmepumpe
  • CE 11-20kw ERP Test Report 1pH DC Inverter Heat Pump Water Heated High Cop Energy Saving Heating/Cooling/Hot Water Warmepumpe

CE 11-20kw ERP Test Report 1pH DC Inverter Heat Pump Water Heated High Cop Energy Saving Heating/Cooling/Hot Water Warmepumpe

Certification: RoHS, CB, CCC, ISO9001, CE, ERP
Working Medium: R32/R290
Heat Source Type: Air Source Heat Pump
Samples:
US$ 2480/Piece 1 Piece(Min.Order)
| Order Sample
Existed color housing
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
CE 11-20kw ERP Test Report 1pH DC Inverter Heat Pump Water Heated High Cop Energy Saving Heating/Cooling/Hot Water Warmepumpe pictures & photos
CE 11-20kw ERP Test Report 1pH DC Inverter Heat Pump Water Heated High Cop Energy Saving Heating/Cooling/Hot Water Warmepumpe
US $2,380-2,650 / Piece
Min. Order: 1 Piece
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2016

Suppliers with verified business licenses

Secured Trading Service
Guangdong, China
Importers and Exporters
The supplier has import and export rights
Experienced Team
The supplier has 10 foreign trading staff(s) and 6 staff(s) with over 6 years of overseas trading experience
Self-branded
The supplier has 5 Self-brands, check the Audit Report for more information
Low MOQ
The MOQ for the supplier's products is 1
to see all verified strength labels (24)
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Certifications
  • Packaging & Shipping
  • Installation Instructions
  • Our Advantages
Overview

Basic Info.

Model NO.
MGSDC-050IC
Transport Package
Polywood Case
Specification
1050*400*1350mm
Trademark
Mango Energy
Origin
China
HS Code
8415812000
Production Capacity
28000 Units/Year

Packaging & Delivery

Package Size
111.00cm * 45.00cm * 146.00cm
Package Gross Weight
130.000kg

Product Description

CE 11-20kw ErP Test Report 1ph DC Inverter Heat Pump Water Heated High Cop Energy Saving Heating/Cooling/Hot Water Warmepumpe
Product Description

CE 11-20kw ERP Test Report 1pH DC Inverter Heat Pump Water Heated High Cop Energy Saving Heating/Cooling/Hot Water Warmepumpe1. Top SCOP in cold, ENERGY SAVING in homeothermy, DC Inverter Dual Rotary compressor and ECO R32 gas for max heat capacity and less refrigerant, large volume of latent heat, even when air temperature is -35ºC.
2.
Ultra frequency conversion technology, mainly drive variable frequency by way of PWM synthesis. It fully integrate power, electronics, micro-PC system and other technologies.
3. Advanced Operate System, ultra intelligent, simple click and fully play the characteristics of
DC inverter frequency conversion system to achieve overlocking performance. Carel Operate System is capacity.
4.
DC mute fan motor, streamline ROHS fan blades, ultra-low noise, durable & reliable, constant max air flow to satisfy enregy supply.
5. Classical European outlook,
rose-gold matte frosted effect housing, fashion taste, never out of time.
6.
WIFI remote control, free of distance, your warm care to all your wife and kids, always with sweet face~

7. Expansion tank and Wilo DC water pump are built in, saving plenty of labor force when installing and maintaining. It mostly decreases working noise, leaving a quiet enough living environment for the whole families.
CE 11-20kw ERP Test Report 1pH DC Inverter Heat Pump Water Heated High Cop Energy Saving Heating/Cooling/Hot Water Warmepumpe

Detailed Photos

CE 11-20kw ERP Test Report 1pH DC Inverter Heat Pump Water Heated High Cop Energy Saving Heating/Cooling/Hot Water WarmepumpeCE 11-20kw ERP Test Report 1pH DC Inverter Heat Pump Water Heated High Cop Energy Saving Heating/Cooling/Hot Water Warmepumpe

Product Parameters
R32 EVI Full inverter Heating&Cooling Heat Pump of New Energy
Model   MGSDC-030IIC MGSDC-050IIC MGSDC-060IIC MGSDC-080IIC
Power Supply V/Ph/Hz 220-240V~/50Hz/1ph, 380-415V/50Hz/3ph
Refrigerant Type   R32
[Space Heating] Ambient Temp. (DB/WB): 7°C/6°C, Water Temp. (Inlet/Outlet): 30°C/35°C
Max Heating Capacity kW 2.32-9.65 3.53-15.76 4.81-18.85 6.36-25.14
Power Input kW 0.38-2.10 0.58-3.49 0.81-4.31 1.08-5.81
COP   6.06-4.59 6.01-4.51 5.89-4.37 5.87-4.33
[Space Heating] Ambient Temp. (DB/WB): 7°C/6°C, Water Temp. (Inlet/Outlet): 50°C/55°C
Max Heating Capacity kW 1.81-7.83 2.38-10.86 2.82-14.12 3.41-17.69
Power Input kW 0.43-3.05 0.58-4.31 0.64-5.34 0.89-7.04
COP   4.15-2.56 4.11-2.52 4.37-2.64 4.32-2.51
[Space Cooling] Ambient Temp. (DB/WB): 35°C / -, Water Temp. (Inlet/Outlet): 12°C/7°C.
Max Cooling Capacity kW 1.43-7.80 2.06-11.40 2.63-14.50 3.31-20.52
Power Input kW 0.32-2.92 0.46-4.3 0.59-5.53 0.76-7.86
COP   4.45-2.68 4.43-2.65 4.41-2.62 4.32-2.61
[Hot Water] Ambient Temp. (DB/WB): 20°C/15°C, Water Temp. from 15°C to 55°C.
Max Heating Capacity kW 10.5 16 19.5 24.8
Power Input kW 2.18 3.36 4.04 5.23
COP   4.82 4.76 4.83 4.74
General Info
ErP Level (35°C)   A+++
ErP Level (55°C)   A++
Electric Heater Rated Input
(Optional)
kW 3
Max. Power Input kW 3.3+3/3.5+3 6+3/6.5+3 6+3/6.5+3 7.7+3/8.0+3
Max. Running Current A 15+13.6/5.3x3+13.6 9.1+13.6/9.85x3+13.6 9.1+13.6/9.85x3+13.6 35+13.6/12.12x3+13.6
Compressor Brand   Panasonic
Circulating Pump Brand
(Optional)
  Wilo
Fan Motor Type   DC motor
Water Side Heat Exchanger   SUS 316 Brazed plate heat exchanger
Air Side Heat Exchanger   Finned Heat Exhanger
Expansion Tank
(Optional)
L 2
Display   Micro processor based digital wire controller with LCD display
Wi-Fi Function   Yes
Rated Water Flow m³/h ≥1.6 ≥2.1 ≥2.7 ≥3.4
Water Pressure Drop kPa 30 38 38 45
Water Pipe Connection inch 1" 1" 1" 1-1/4"
Sound Pressure Level at 1m dB(A) 43~54 43~55 44~55 45~58
Operation Range °C -30~43
Max. Outlet Water Temp. °C 55~60
Water Proof Class   IPX4
Electricity Shock Proof   I
Net Weight kg 76 120 140 165
Gross Weight kg 84 130 150 180
Net Dimensions (L×W×H) mm 925X375X770 1050X400X1350 1050X400X1350 1175X400X1482
Package Dimensions (L×W×H) mm 980X410X885 1105X445X1455 1105X445X1455 1200X490X1565

Curves of Heating Capacity & COPof CE 11-20kw ErP Test Report 1ph DC Inverter Heat Pump Water Heated High Cop Energy Saving Heating/Cooling/Hot Water Warmepumpe
CE 11-20kw ERP Test Report 1pH DC Inverter Heat Pump Water Heated High Cop Energy Saving Heating/Cooling/Hot Water Warmepumpe

Certifications

CE certificates of CE 11-20kw ErP Test Report 1ph DC Inverter Heat Pump Water Heated High Cop Energy Saving Heating/Cooling/Hot Water WarmepumpeCE 11-20kw ERP Test Report 1pH DC Inverter Heat Pump Water Heated High Cop Energy Saving Heating/Cooling/Hot Water WarmepumpeErP Test Report & ErP Labels of CE 11-20kw ErP Test Report 1ph DC Inverter Heat Pump Water Heated High Cop Energy Saving Heating/Cooling/Hot Water Warmepumpe
CE 11-20kw ERP Test Report 1pH DC Inverter Heat Pump Water Heated High Cop Energy Saving Heating/Cooling/Hot Water Warmepumpe

Packaging & Shipping

All shipments are available to proceed on CE 11-20kw ErP Test Report 1ph DC Inverter Heat Pump Water Heated High Cop Energy Saving Heating/Cooling/Hot Water WarmepumpeCE 11-20kw ERP Test Report 1pH DC Inverter Heat Pump Water Heated High Cop Energy Saving Heating/Cooling/Hot Water Warmepumpe

Installation Instructions

Domestic hot water, house/space heating/cooling are capacity in one system with our All in One design of CE 11-20kw ErP Test Report 1ph DC Inverter Heat Pump Water Heated High Cop Energy Saving Heating/Cooling/Hot Water Warmepumpe
CE 11-20kw ERP Test Report 1pH DC Inverter Heat Pump Water Heated High Cop Energy Saving Heating/Cooling/Hot Water Warmepumpe
CE 11-20kw ERP Test Report 1pH DC Inverter Heat Pump Water Heated High Cop Energy Saving Heating/Cooling/Hot Water WarmepumpeCE 11-20kw ERP Test Report 1pH DC Inverter Heat Pump Water Heated High Cop Energy Saving Heating/Cooling/Hot Water Warmepumpe

Our Advantages

CE 11-20kw ERP Test Report 1pH DC Inverter Heat Pump Water Heated High Cop Energy Saving Heating/Cooling/Hot Water Warmepumpe

Any Concernings are warmly welcome to send an inquiry on CE 11-20kw ErP Test Report 1ph DC Inverter Heat Pump Water Heated High Cop Energy Saving Heating/Cooling/Hot Water Warmepumpe!!!

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now