A+++ CE 40kw R32 COP5.0 WIFI Low Temperature GEOTHERMAL Water Source Heat Pump Water Heater Floor Heating Domestic Hot Water Geyser
Product Features:
1) Most Safe: Eliminated all problems of traditional water boiler, seperating all, heat source, electric power, heated/chilled sides.
2) Super Reliable: Service life reaches 15 years, even longer, minimum annual maintenance cost.
3)All-weather Operation: Not being effected by weather, snow or rain, even severe air condition, in summer or winter.
4) Environment Friendly: Neither pollution nor waste discharges during entire operate cycle.
5) Economy: Its running costs 4-5 time less than those of traditional (gas/oil) water boiler he-
ating system.
6) Energy Balance: The working fluid transfers heat energy from water (groundwater/water) to hot water for domestic or industrial use: House heating in winter or 4-season domestic hot water.
7) Modular design: More units connection in 1 system is compatible in our Operate System up to various project requirement.
8) Mute operate noise: Sound-off by aviation soundproof foam and device housing sealed.
9) WIFI or RS485 remote control: Free-of-hand Operate System is available frequently.
Certificates of A+++ CE 40kw R32 COP5.0 WIFI Low Temperature GEOTHERMAL Water Source Heat Pump Water Heater Floor Heating Domestic Hot Water Geyser
Product Specifications of A+++ CE 40kw R32 COP5.0 WIFI Low Temperature GEOTHERMAL Water Source Heat Pump Water Heater Floor Heating Domestic Hot Water Geyser
Water Source Heat Pump for Floor Heating
Model |
MG-03SFXRS |
MG-03SFXRS/380 |
MG-05SFXRS |
MG-06SFXRS |
MG-10SFXRS |
MG-12SFXRS |
Specifications |
Heating input power |
KW |
2.13 |
2.39 |
4.25 |
5.08 |
8.5 |
10.16 |
Heating capacity |
KW |
10.4 |
11.6 |
20.8 |
24.7 |
41.6 |
49.4 |
COP |
|
4.88 |
4.85 |
4.89 |
4.86 |
4.89 |
4.86 |
Rated current |
A |
13 |
6 |
8.8 |
11.1 |
17.6 |
20.7 |
Max outlet water temp |
ºC |
60 |
60 |
60 |
60 |
60 |
60 |
Rated outlet water temp |
ºC |
55 |
55 |
55 |
55 |
55 |
55 |
Hot water capacity |
L/H |
224 |
249 |
447 |
531 |
894 |
1062 |
Water flow of load side |
L/h |
2100 |
2100 |
3200 |
3800 |
4800 |
6200 |
water flow of source side |
L/h |
1800 |
2010 |
3650 |
4300 |
7401 |
8774 |
Water pressure drop |
Kpa |
≥70 |
≥70 |
≥70 |
≥70 |
≥80 |
≥80 |
pipe size |
mm |
25 |
25 |
25 |
25 |
32 |
32 |
noise |
db |
50 |
50 |
50 |
50 |
50 |
55 |
net weight |
kg |
88 |
88 |
120 |
130 |
280 |
300 |
gross weight |
kg |
92 |
92 |
130 |
140 |
295 |
315 |
Level of protection |
IPX4 |
IPX4 |
IPX4 |
IPX4 |
IPX4 |
IPX4 |
Electric shock proof grade |
I |
I |
I |
I |
I |
I |
Standard
components |
cabinet |
|
Galvanized sheet/ Spray coating / gray color |
dimension |
mm |
710*520*1000 |
710*520*1000 |
710*520*1000 |
710*520*1000 |
1280*830*800 |
1280*830*800 |
packing dimension |
mm |
760*570*1130 |
760*570*1130 |
760*570*1130 |
760*570*1130 |
1330*880*930 |
1330*880*930 |
Refrigerant |
|
R410/R32 |
Power supply |
|
220V~240V/50Hz/1ph |
380V~415V/50Hz/3ph |
Power supply L wire line |
Mm2 |
2.5 |
2.5 |
4 |
6 |
6 |
6 |
Power supply N wire line |
Mm2 |
|
1.5 |
2.5 |
2.5 |
2.5 |
2.5 |
noise |
db(A) |
50 |
50 |
50 |
50 |
50 |
55 |
compressor model |
|
ZW30KAE |
ZW34KAE |
ZW61KAE |
ZR72KCE |
ZR61KCE |
ZW72KAE |
compressor |
|
Copeland 1pc |
Copeland 1pc |
load side HE |
|
Double-pipe heat exchanger |
source side HE |
|
plate heat exchanger |
Thermal expansion valve |
|
Emerson 3Ton |
Emerson 5Ton |
Emerson 6Ton |
Emerson 5Ton*2 |
Emerson 6Ton*2 |
AC contactor and thermal relay |
Fuji |
Controller |
|
multiple function controller |
Protection function |
Tempreature protection, time protection, water flow protection, antifreeze protection, current protection |
Water pressure switch |
0.015Mpa :OFF, 0.03Mpa: ON |
High pressure switch |
3.0/3.4MPa |
Low pressure switch |
0.15/0.32MPa |
Package |
Polywood case |
working mode |
|
heating mode |
Product Images of A+++ CE 40kw R32 COP5.0 WIFI Low Temperature GEOTHERMAL Water Source Heat Pump Water Heater Floor Heating Domestic Hot Water Geyser
Work Principle 01 of A+++ CE 40kw R32 COP5.0 WIFI Low Temperature GEOTHERMAL Water Source Heat Pump Water Heater Floor Heating Domestic Hot Water Geyser
Work Principle 02 of A+++ CE 40kw R32 COP5.0 WIFI Low Temperature GEOTHERMAL Water Source Heat Pump Water Heater Floor Heating Domestic Hot Water Geys
Operate Principle of A+++ CE 40kw R32 COP5.0 WIFI Low Temperature GEOTHERMAL Water Source Heat Pump Water Heater Floor Heating Domestic Hot Water Geys:
Installation of A+++ CE 40kw R32 COP5.0 WIFI Low Temperature GEOTHERMAL Water Source Heat Pump Water Heater Floor Heating Domestic Hot Water Geys:
Application of A+++ CE 40kw R32 COP5.0 WIFI Low Temperature GEOTHERMAL Water Source Heat Pump Water Heater Floor Heating Domestic Hot Water Geys:
Send an inquiry right away, for more detail on A+++ CE 40kw R32 COP5.0 WIFI Low Temperature GEOTHERMAL Water Source Heat Pump Water Heater Floor Heating Domestic Hot Water Geys! Up to 20%-30% discount would be presented as VIP clients!