22kw R32 Evi Split Heat Pump Air Source DC Inverter Water Heater Pump with Heating Cooling Hot Water

Product Details
Customization: Available
Energy Efficiency Grade: Three
Heat Temperature: 55-60 Degree
Still deciding? Get samples of US$ 2250/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2016

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Experienced Team
The supplier has 10 foreign trading staff(s) and 6 staff(s) with over 6 years of overseas trading experience
Self-branded
The supplier has 6 Self-brands, check the Audit Report for more information
Low MOQ
The MOQ for the supplier's products is 1
to see all verified strength labels (24)
  • 22kw R32 Evi Split Heat Pump Air Source DC Inverter Water Heater Pump with Heating Cooling Hot Water
  • 22kw R32 Evi Split Heat Pump Air Source DC Inverter Water Heater Pump with Heating Cooling Hot Water
  • 22kw R32 Evi Split Heat Pump Air Source DC Inverter Water Heater Pump with Heating Cooling Hot Water
  • 22kw R32 Evi Split Heat Pump Air Source DC Inverter Water Heater Pump with Heating Cooling Hot Water
  • 22kw R32 Evi Split Heat Pump Air Source DC Inverter Water Heater Pump with Heating Cooling Hot Water
  • 22kw R32 Evi Split Heat Pump Air Source DC Inverter Water Heater Pump with Heating Cooling Hot Water
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Features
  • Key parts
  • Instalation Reference
  • Mango′s factory
  • Mango′s Project
Overview

Basic Info.

Model NO.
MGSDC-060IIC
Heat Source
Air-source
Heating Type
Circulating Heat
Application
Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Certification
CE, ISO9001, CCC
Transport Package
Wood
Specification
1415 x 455 x 1472
Trademark
Mango
Origin
Guangzhou
HS Code
8418612090
Production Capacity
500000

Product Description

 

Product Description

A+++ ERP Sprusn 22KW R32 EVI split Heat Pump Air Source DC Inverter Water Heater Pump with Heating Cooling Hot Water

22kw R32 Evi Split Heat Pump Air Source DC Inverter Water Heater Pump with Heating Cooling Hot Water
1.R32 Refrigerant pipe connection for best system stability even in tough weather.
2.E-heater, diverter valve,water pump,and expansion tank can be included
3.A+++ Energy Rating Level,with CE,TUV test report.
4.Low noise sound power level as low as 45 dB(A)
5.Work down to -30 degree C
6.WIFI solution available,Carel controller.
7.Function: Heating +Cooling+ Hot water
 
Product Parameters
Model   MGSDC-030IIC MGSDC-050IIC MGSDC-060IIC MGSDC-080IIC
Power Supply V/Ph/Hz 220-240V~/50Hz/1ph, 380-415V/50Hz/3ph
Refrigerant Type   R32
[Space Heating] Ambient Temp. (DB/WB): 7°C/6°C, Water Temp. (Inlet/Outlet): 30°C/35°C
Max Heating Capacity kW 2.32-9.65 3.53-15.76 4.81-18.85 6.36-25.14
Power Input kW 0.38-2.10 0.58-3.49 0.81-4.31 1.08-5.81
COP   6.06-4.59 6.01-4.51 5.89-4.37 5.87-4.33
[Space Heating] Ambient Temp. (DB/WB): 7°C/6°C, Water Temp. (Inlet/Outlet): 50°C/55°C
Max Heating Capacity kW 1.81-7.83 2.38-10.86 2.82-14.12 3.41-17.69
Power Input kW 0.43-3.05 0.58-4.31 0.64-5.34 0.89-7.04
COP   4.15-2.56 4.11-2.52 4.37-2.64 4.32-2.51
[Space Cooling] Ambient Temp. (DB/WB): 35°C / -, Water Temp. (Inlet/Outlet): 12°C/7°C.
Max Cooling Capacity kW 1.43-7.80 2.06-11.40 2.63-14.50 3.31-20.52
Power Input kW 0.32-2.92 0.46-4.3 0.59-5.53 0.76-7.86
COP   4.45-2.68 4.43-2.65 4.41-2.62 4.32-2.61
[Hot Water] Ambient Temp. (DB/WB): 20°C/15°C, Water Temp. from 15°C to 55°C.
Max Heating Capacity kW 10.5 16 19.5 24.8
Power Input kW 2.18 3.36 4.04 5.23
COP   4.82 4.76 4.83 4.74
General Info
ErP Level (35°C)   A+++
ErP Level (55°C)   A++
Max. Power Input kW 3.3+3/3.5+3 6+3/6.5+3 6+3/6.5+3 7.7+3/8.0+3
Max. Running Current A 15+13.6/15.9x3+3 9.1+13.6/9.85x3+13.6 9.1+13.6/9.85x3+13.6 35+13.6/12.12x3+13.6
Electric Heater Rated Input
(Optional)
kW 2KW/3KW/6KW
Fan Motor Type   DC motor
Water Side Heat Exchanger   SUS 316 Brazed plate heat exchanger
Air Side Heat Exchanger   Finned Heat Exhanger
Expansion Tank
(Optional)
L 2
Display   Micro processor based digital wire controller with LCD display
Wi-Fi Function   Yes
Rated Water Flow m³/h ≥1.6 ≥2.1 ≥2.7 ≥3.4
Water Pressure Drop kPa 30 38 38 45
Water Pipe Connection inch 1" 1" 1" 1-1/4"
Sound Pressure Level at 1m dB(A) 43~54 43~55 44~55 45~58
Operation Range °C -30~43
Max. Outlet Water Temp. °C 55~60
Water Proof Class   IPX4
Electricity Shock Proof   I
Net Weight kg 76 120 140 165
Net Dimensions (L×W×H) mm 925X375X745 1050X400X1350 1050X400X1350 1175X400X1482
 
Features
A.Top SCOP
Inverter Rotary compressor and ECO R32/R410 refrigerant for max heat capacity and less
refrigerant, large volume of latent heat from the air via evaporator in coldest season.
B.Ultra frequency conversion technology
Based on the principle of proportional relationship between motor speed and input frequency of working power supply: n = 60f(1-s)/p and changing motor speed by changing working power frequency of the motor, it adopts AC-DC-AC power conversion technology, relying on our powerful control system with PWM generation ability, integrate V/F, vector control (VC) and direct torque control (DTC) to achieve control method of variable frequency PID calculus, mainly drive variable frequency by way of PWM synthesis drive, fully integrate power, electronics, microcomputer control and other technologies.
C.Advanced Carel Operate System, ultra intelligent
Especially superior heat dissipation circuit board design, longer service, over 3 time of other brand's, simple click and fully
play the characteristics of DC inverter frequency conversion system to achieve overlocking performance.
D.Multi-speed mute fan motor
ROHS fan blades, ultra-low noise, durable & reliable, constant max air flow to satisfy heat supply.
E.Soft-start and soft-shutdown
Protecting both electrical system and all key parts, such a EEV, SANHUA 4-way valve, LG AC contactor & other World famous brand components ensure heat pump device 2-3 time longer service by
1) making output torque of the motor meeting the requirements of mechanical system for starting torque, ensuring smooth acceleration & smooth transition, and avoiding destructive torque impact;
2) achieving both starting current meeting the requirements of motor's bearing capacity, and the insulation damage or burnout caused when it starts.
3) reducing both voltage sag range and the content of high-order harmonics etc.
F.High-tech shock-absorption all copper construction piping
High-accurate completely automatic silver welding, easy maintenance.
G.High-density protective jacket for minimum heat lost
Aviation class insulation foam with outstanding sound absorption.
H.Classic European outlook forming
Fashion taste, never out of time.
I.Portable compact design
Saving room for installation & operation.
J.Fast heating and cooling speed
Before the indoor temperature reaches the set value, the  rotary compressor delivers high levels of efficiency, enabling the unit to operate at high frequency so that it can heat water or provide house heating/cooling at a faster speed.
22kw R32 Evi Split Heat Pump Air Source DC Inverter Water Heater Pump with Heating Cooling Hot Water

 

Key parts
Mango energy domestic all in one heat pump heat pump inverter heat pump for heating cooling water heaters
1) More compact with slim body;
2) Much lighter for transportation & stallation;
3) Dual rotary, more stable operating & lower operate noise, more ECO;
4) Permanent magnet, no power driving, rapidly ware & tear decreasing, higher efficient.
5) R32, R410A refrigerants are capable, green enough for the world.
Hydrophilic plus-size-area fins, ripple copper pipe...
22kw R32 Evi Split Heat Pump Air Source DC Inverter Water Heater Pump with Heating Cooling Hot Water
 
Instalation Reference

22kw R32 Evi Split Heat Pump Air Source DC Inverter Water Heater Pump with Heating Cooling Hot Water
 
Mango's factory

22kw R32 Evi Split Heat Pump Air Source DC Inverter Water Heater Pump with Heating Cooling Hot Water22kw R32 Evi Split Heat Pump Air Source DC Inverter Water Heater Pump with Heating Cooling Hot Water

Our quality management system was certified in conformity with ISO9001 Standard, heat pumps with CE, TUV, ErP, certificated.
And also with customized OEM/ODM services for distributors all over the world.Now Mango brand heat pump has been
exported to more than 100 countries, even well installed.
Mango's Project

 

22kw R32 Evi Split Heat Pump Air Source DC Inverter Water Heater Pump with Heating Cooling Hot Water

PRAISE FROM CUSTOMERS
22kw R32 Evi Split Heat Pump Air Source DC Inverter Water Heater Pump with Heating Cooling Hot Water

Send your inquiry, right away!
For detail of our Mango energy domestic all in one heat pump heat pump inverter heat pump for heating cooling water heaters

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Groups
More